KE10.504 connector can be used for aluminium and copper conductors. Tightening torque is 10 Nm. The connectors are used either inside metal poles or in separate boxes.
Code | KE10.504 |
GTIN | 6418677400087 |
Name | Branching connector |
Branching connector KE10.504
KE10.504 connector can be used for aluminium and copper conductors. Tightening torque is 10 Nm. The connectors are used either inside metal poles or in separate boxes.
Code | KE10.504 |
GTIN | 6418677400087 |
Name | Branching connector |
Standards | |
---|---|
Standards | IEC 61238-1 |
Others | |
ETIM Class | EC000306 |
Dimensions | |
Weight | 0.058 kg |
Height | 38 mm |
Length | 64 mm |
Conductor size Al | 10 ... 50 mm² |
Conductor size Cu | 2.5 ... 35 mm² |
Conductor diameter | 2 ... 10.2 mm |
Electrical values | |
Highest system voltage | 1 kV |
Mechanical | |
Tightening torque Nm | 10 Nm |
ETIM | |
---|---|
Model | Branch |
Colour insulation | Colourless |
Grease filling against corrosion | Yes |
Nominal cross section | 2.5 ... 50 mm² |
Max. number of cores | 1 |
Interrupt free shifting | Yes |
Carton | |
---|---|
Size | 50 pcs |
Depth | 215 mm |
Height | 120 mm |
Width | 215 mm |
Weight | 3.200 kg |
Volume | 5.547 l |
Pallet package | |
Size | 5250 pcs |
Depth | 1200 mm |
Height | 890 mm |
Width | 800 mm |
Weight | 356.000 kg |
Volume | 854.4 l |
Name | Code | GTIN | ||
---|---|---|---|---|
Cover for connector KE10In the areas where connectors are exposed to frequent high humidity and water condensation the connectors can be equipped with PMR2680.4 covers. Cover will give extra tolerance against rough conditions. It is also designed for installations where double insulation is a requirement or if the voltage is continuously on.The transparent material makes it possible to see which connector (white or blue) is inside, without removing the cover. One set contains four covers.Cover is suitable for K |
PMR2680.4 | 6438100308384 | See product |
Name | Code | GTIN | ||
---|---|---|---|---|
Lamp post fuse baseLFB16-R fusebase is equipped with 4 mm² Cu cable as a feeder. Cable from lamp to fuse base can be between 1.5-6 mm² Cu. Max. fuse size is 16A. Includes a 6A fuse. |
LFB16-06A-R | 6438100321253 | See product | |
Lamp post fuse baseLFB16-R fusebase is equipped with 4 mm² Cu cable as a feeder. Cable from lamp to fuse base can be between 1.5-6 mm² Cu. Max. fuse size is 16A. Includes 10A fuse. |
LFB16-10A-R | 6438100321260 | See product | |
Lamp post fuse baseLFB16-R fuse base is equipped with 10 mm² Cu cable as a feeder. Cable from lamp to fuse base can be between 1.5-6 mm² Cu. Max. fuse size is 6A. Includes 6A fuse. |
LFB06.1-06A-R | 6438100327941 | See product | |
Lamp post fuse baseLFB16-R fuse base is equipped with 10 mm² Cu cable as a feeder. Cable from lamp to fuse base can be between 1.5-6 mm² Cu. Max. fuse size is 10A. Includes 10A fuse. |
LFB10.1-10A-R | 6438100327934 | See product | |
Lamp post fuse baseLFB16-R fuse base is equipped with 10 mm² Cu cable as a feeder. Cable from lamp to fuse base can be between 1.5-6 mm² Cu. Max. fuse size is 16A. Includes 6A fuse. |
LFB16.1-06A-R | 6438100320966 | See product |
Al 4x10-35 mm² / Cu 1.5-25 mm²
Code: KE10.1
GTIN: 6418677400049
Al 4x10-35 mm² / Cu 1.5-25 mm²
Code: KE10.1N
GTIN: 6438100330705
Al 6x10-35 mm² / Cu 1.5-25 mm²
Code: KE10.3
GTIN: 6418677400063
Al 4x10-50 mm² / Cu 2.5-35 mm²
Code: KE10.504N
GTIN: 6418677455421